| Technical Data |
| Input voltage | solar panels 15 - 30 V/DC open circuit voltage, 12 V/DC rated voltage
| | Max. charging current | total 16 A (2 accumulators of max. 8 A each or 1 accumulator connected in parallel at both outputs up to 16 A)
| | Connections | 1 or 2 accumulators 12 V/DC. When connecting only 1 accumulator, it has to be connected at connection "2".
| | Displays | one display per accumulator "accumulator is charging", 1 display | | Cooling | In case of currents > 4 A the module has to be screwed with the metal bottom on a heat sink with a surface of > 300 sq. cm.
| | Fuse | A pre-fuse F16 A is necessary (not included)
| | Switch-on voltage | accumulator approx. < 13,4 V/DC (± 5 %)
| | Switch-off voltage | "accumulator charged" ca. 14,4 V/DC (± 5 %)
| | Own current consumption (is taken from the accumulator) | < 2 mA
| | Reverse current-proof (no additional diode required)
| | Dimensions | ca. 87 x 60 x 32 mm |
To be connected between a solar panel 12 V/DC and 1 or 2 accumulators in order to avoid an overload of the accumulators. If 2 accumulators are connected, they are charged separately from each other. The accumulator with lowest charging voltage always receives more charging current. With LED displays and high charging capacity: max. 2 x 8 A or 1 x 16 A.
|