Technical Data |
Operating voltage | 110 - 240 V/AC
| Current | max. 12 A. At 110 V/AC this corresponds to max. 1320 VA and to max. 2880 VA at 240 V/AC.
| Load | max. 2600 VA
| Required potentiometer | 470 k lin. (not enclosed)
| Dimensions | approx. 60 x 56 x 20 mm (without fastening straps) |
Control of resistive + inductive loads (e.g. motors, heatings, incandescent lamps, etc., if they are phasecontrollable). It is not possible to control: e.g. fluorescent lamps, motors with starting capacitor.
Available attachments: M150 - DC + pulse converter. When superposing this module, it also possible to control the power control M028 with control voltages (1 - 5 V/DC or 3 - 12 V/DC or 6 - 24 V/DC) or with TTL pulses (optionally in each case).
Please notice the article "Dosierte Leistung" from the german magazine "Electronic Actuell Magazin" no. 4/99.
Available accessory: M150 - DC + pulse converter
|