| Technical Data |
| Operating voltage | 12 V/AC (10 - 14 V/AC) alternating voltage 50 - 60 Hz (for normal iron core transformers only, not for electronic halogen transformers)
| | Working mode | phase control
| | Loading capacity | for ohmic or inductive loads such as lamps, motors, electromagnets etc. up to 50 W (4,5A)
| | Dimensions | approx. 60 x 57 x 23 mm (without fixing straps) |
controls continuously 12 V/AC incandescent lamps (e.g. halogen lamps), 12 V/AC heatings, motors (also direct current motors with added rectifier), etc.. Only to be operated at a 12 V/AC transformer (50 -60 Hz), not suitable for DC voltage (accumulator)! It is also possible to control 24 V/AC (linear potentiometer 2.2 k) or 48 V/AC (linear potentiometer 4.7 k) by exchanging the potentiometer.
|